Pompe à jet d’eau 90K 72165539 tête d’étanchéité

Catégorie:

Description

Sealing Head 72165539 is a important spare part of 90K waterjet pump.

Assemblage de l’intensificateur 72170165
Assemblage de l’intensificateur 72170165

Article

Numéro de pièceDescriptionQuantitéArticleNuméro de pièceDescriptionQuantité

1

05146592Joint d’étanchéité, Topworks Support21472162253Ventouse

2

2

20476377Soutien, Topworks21505130091Cartouche de joint hydraulique

2

3

10118206Joint torique, 1.31×1.56× .1321672175989Bride de retenue de bague2

4

05144514Vérin hydraulique11772158494Assemblage de joints UHP

2

5

05098991Vis à tête creuse, 3/8-16×3-3/481872166738Cylindre UHP

2

6

95688743Rondelle de blocage, .3881972163802Paquebot

2

7

72101190Assemblage du piston12020474325Goujon, 1-1/8-12×18.31

8

8

10074771Joint torique, 5.25×5.50× .1322172170157Assemblage de la tête de scellage

2

9

05120092Anneau de secours, 5.25×5.50× .1322272178493Assemblage de brides

2

10

72175997Culasse hydraulique22320464590Rondelle plate, 1.13

8

11

05097886Vis à tête creuse, 3/4-16×2-1/4122420461761Écrou hexagonal, 1-1/8-12

8

12

05144183Ensemble d’entretoise, interrupteur de proximité22520489339Adaptateur, JIC/Tuyau, 50× .38

1

05144191

Joint torique, .69× .88× .092672176756Joint torique, 3,88×4,25× .19

6

13

72141569Kit, Détecteur de proximité2

72134224Commutateur de proximité

95119012

Vis à tête creuse, 1/4-20×1

90K-Pompe à jet d’eau-72165539-Tête d’étanchéité
90K-Pompe à jet d’eau-72165539-Tête d’étanchéité

The sealing head of a waterjet pump is a critical part that helps to maintain the pressure and flow of water through the pump.

The sealing head is located at the top of the waterjet pump and is responsible for sealing the high-pressure water inside the system, preventing leaks and ensuring that the water is directed to the cutting or cleaning tool.

The sealing head typically consists of several components, including the plunger, the seal, and the check valve. The plunger is a piston-like component that moves up and down to create the high-pressure water stream. The seal is a specialized component that is designed to prevent water from escaping through the top of the waterjet pump.

The check valve is designed to govern the flow of water through the system and preventing backflow.

90K-Waterjet-Pump
90K-Waterjet-Pump

It is essential that the sealing head is properly maintained and inspected to make sure that it is functioning correctly. Regular maintenance and inspection can help to stem leaks and other issues that can affect the performance and efficiency of the waterjet pump system.

The frequency of inspection for the sealing head of a waterjet pump depends on several factors, including the intensity of use, the operating conditions, and our manufacturer’s recommendations. However, as a general rule, it is recommended to inspect the sealing head at least once a year or after every 1,000 hours of operation, whichever comes first.

During the inspection, you should check the condition of the plunger, seal, and check valve for any signs of wear or damage. You should also inspect the inlet and outlet fittings, pressure gauge, and relief valve to ensure that they are functioning correctly and not leaking.

If any issues or signs of wear are detected during the inspection, it is recommended to replace the affected components as soon as possible to prevent any further damage or potential safety hazards.

However, the frequency of inspection may vary depending on the specific pump model. Therefore, it is always best to consult our manufacturer’s guidelines or seek advice from a qualified technician to determine the appropriate inspection frequency for your specific waterjet pump.