Piston Assembly 72101190 applied to 90k psi waterjet intensifier pump.

Assemblage de l’intensificateur 72170165
Assemblage de l’intensificateur 72170165

Article

Numéro de pièceDescriptionQuantitéArticleNuméro de pièceDescriptionQuantité

1

05146592Joint d’étanchéité, Topworks Support21472162253Ventouse

2

2

20476377Soutien, Topworks21505130091Cartouche de joint hydraulique

2

3

10118206Joint torique, 1.31×1.56× .1321672175989Bride de retenue de bague2

4

05144514Vérin hydraulique11772158494Assemblage de joints UHP

2

5

05098991Vis à tête creuse, 3/8-16×3-3/481872166738Cylindre UHP

2

6

95688743Rondelle de blocage, .3881972163802Paquebot

2

7

72101190Assemblage du piston12020474325Goujon, 1-1/8-12×18.31

8

8

10074771Joint torique, 5.25×5.50× .1322172170157Assemblage de la tête de scellage

2

9

05120092Anneau de secours, 5.25×5.50× .1322272178493Assemblage de brides

2

10

72175997Culasse hydraulique22320464590Rondelle plate, 1.13

8

11

05097886Vis à tête creuse, 3/4-16×2-1/4122420461761Écrou hexagonal, 1-1/8-12

8

12

05144183Ensemble d’entretoise, interrupteur de proximité22520489339Adaptateur, JIC/Tuyau, 50× .38

1

05144191

Joint torique, .69× .88× .092672176756Joint torique, 3,88×4,25× .19

6

13

72141569Kit, Détecteur de proximité2

72134224Commutateur de proximité

95119012

Vis à tête creuse, 1/4-20×1

90k psi Waterjet Piston Assembly 72101190
90k psi Waterjet Piston Assembly 72101190

What are some common mistakes to avoid when cleaning the piston assembly of 90k psi waterjet pump?

1. Using harsh chemicals or abrasive materials

Using harsh chemicals or abrasive materials can damage the surfaces of the piston assembly, leading to reduced performance or premature failure. It’s important to use a high-quality cleaning agent that is compatible with the materials in the piston assembly 90k psi waterjet pump.

2. Using metal tools

Metal tools can scratch or damage the surfaces of the piston assembly, leading to reduced performance or premature failure. It’s important to use appropriate tools such as brushes or swabs that are made from non-metallic materials.

3. Neglecting to flush the system

After cleaning the piston assembly, it’s important to flush the 90k psi waterjet system with clean water to remove any remaining debris or cleaning agent. Neglecting to flush the system can lead to clogs or reduced performance of the 90k psi waterjet system.

4. Over-tightening the piston seals

Over-tightening the piston seals can cause them to deform or become damaged, leading to leaks or reduced performance of the system. It’s important to follow manufacturer’s recommendations for tightening the piston seals.

5. Neglecting to inspect the piston seals

Inspecting the piston seals for wear or damage is an important part of the cleaning process. Neglecting to inspect the piston seals can lead to leaks or reduced performance of the 90k psi waterjet system.

6. Neglecting to record the maintenance

Recording the cleaning and flushing in the maintenance log is an important part of regular maintenance. Neglecting to record the maintenance can make it difficult to keep track of when the piston assembly was last serviced and to ensure that regular maintenance is performed.