Kit de piezas de repuesto de chorro de agua 20477518 de 90.000 PSI de conjunto de válvula neumática / actuador, normalmente abierto 20468634

Categoría:

Descripción

90,000 PSI Waterjet Spare Parts Kit 20477518 of Pneumatic Valve/Actuator Assembly, Normally Open 20468634

Includes items 2, 4, 5, 6, 9, 10 and 16

Conjunto de válvula neumática / actuador, normalmente abierto 20468634
Conjunto de válvula neumática / actuador, normalmente abierto 20468634

Artículo

Número de piezaDescripciónCantidadArtículoNúmero de piezaDescripción

Cantidad

1

20468617Valve Body1910074714O-Ring, 2.44 x 2.63 x .091

2

10178697Valve Seat11010074565O-Ring, 2.25 x 2.38 x .062

3

20451557UHP Adapter111BV501184Pistón1

4

72112069Montaje del sello11220452965Collar UHP, .381

5

20475874Backup Ring, Bronze11320452956Glándula UHP, .381

6

20475878Valve Stem11420452959UHP Collar, .251

7

20468601Pneumatic Cylinder11520452962UHP Gland, .251

8

BV601184Cylinder Head11620475882Backup Ring, SST1

20477518 Kit de piezas de repuesto

Includes items 2, 4, 5, 6, 9, 10 and 16

The pneumatic valve/actuator assembly, normally open used in a 90,000 waterjet pump is a critical component of the hydrojet cutter system.

It controls the flow of high-pressure water through the cutting nozzle.

In the hydrojet cutter system, the pneumatic valve/actuator assembly is typically used to control the on/off function of the cutting water.

When the control signal is applied, the actuator compresses the spring to close the valve and stop the flow of water.

When the control signal is removed, the spring returns the valve to the open position, allowing the water to flow through the nozzle.

It is important to ensure that the pneumatic valve/actuator assembly is properly maintained and serviced to ensure optimal performance and avoid downtime.

Regular inspection, cleaning, and replacement of worn or damaged components is essential to keep the hydrojet cutter system running smoothly and safely.

There are several signs that may indicate that the Pneumatic Valve/Actuator Assembly, Normally Open used in your 90,000 psi waterjet pump needs to be replaced:

1. Leakage

If you notice water leaking from the valve or actuator assembly, this may indicate that there is a seal or gasket that needs to be replaced.

2. Reduced flow

If you notice a decrease in the flow of water through the cutting nozzle, this may indicate that the valve is not opening fully or that there is a blockage in the valve or actuator assembly.

3. Failure to open or close properly

If the valve fails to open or close properly in response to the control signal, this may indicate that the actuator is not providing sufficient force to operate the valve.

4. Unusual sounds or vibrations

If you notice unusual sounds or vibrations coming from the valve or actuator assembly, this may indicate that there is a problem with the assembly.

If you notice any of these signs, it is recommended to consult with the manufacturer or a qualified service provider to diagnose and address the underlying issue.

In some cases, it may be possible torepair the valve and actuator assembly by replacing individual components, such as seals or gaskets.

In other cases, it may need to replace the entire assembly.

It is important to address any issues with the valve and actuator assembly promptly to avoid further damage or downtime.

Any other questions about 90000 psi waterjet products and hydrojet cutters, please contáctenos.