90k psi Waterjet Pump 20489339 Adapter, JIC/Pipe, .50 x .38

Categoría:

Descripción

Adapter, JIC/Pipe, .50 x .38 20489339 applied to 90k psi waterjet pump.

Montaje del intensificador 72170165
Montaje del intensificador 72170165

Artículo

Número de piezaDescripciónCantidadArtículoNúmero de piezaDescripciónCantidad

1

05146592Junta, soporte de Topworks21472162253Desatascador

2

2

20476377Soporte, Topworks21505130091Cartucho de sello hidráulico

2

3

10118206Junta tórica, 1.31×1.56× .1321672175989Brida de retención de buje2

4

05144514Cilindro hidráulico11772158494Conjunto de sello UHP

2

5

05098991Tornillo de cabeza de zócalo, 3/8-16×3-3/481872166738Cilindro UHP

2

6

95688743Arandela de cerradura, .3881972163802Liner

2

7

72101190Conjunto de pistón12020474325Stud, 1-1/8-12×18.31

8

8

10074771Junta tórica, 5.25×5.50× .1322172170157Conjunto de cabezal de sellado

2

9

05120092Anillo de respaldo, 5.25×5.50× .1322272178493Montaje de brida

2

10

72175997Culata hidráulica22320464590Lavadora plana, 1.13

8

11

05097886Tornillo de cabeza de zócalo, 3/4-16×2-1/4122420461761Tuerca hexagonal, 1-1/8-12

8

12

05144183Conjunto del espaciador, interruptor de proximidad22520489339Adaptador, JIC/tubería, 50× .38

1

05144191

Junta tórica, .69× .88× .092672176756Junta tórica, 3.88×4.25× .19

6

13

72141569Kit, interruptor de proximidad2

72134224Interruptor de proximidad

95119012

Tornillo de cabeza de zócalo, 1/4-20×1

1. Material

The Adapter 20489339 is typically made from a high-strength material such as stainless steel or brass.

These materials are chosen for their resistance to corrosion and their ability to withstand the high pressures and forces generated in 90k psi waterjet pump.

2. Thread Sizes

The Adapter 20489339 has a thread size of .50 inches on one end and a thread size of .38 inches on the other end.

These sizes are commonly used in 90k psi waterjet pump, and the adapter allows pipes or hoses with different thread sizes to be connected together.

3. Fitting Type

The JIC side of the adapter is a 37-degree flare fitting with a male thread, while the Pipe side of the adapter has a female thread.

The 37-degree flare fitting provides a secure connection between the adapter and the hose or pipe.

The female pipe thread allows the adapter to be connected to another pipe or fitting.

4. Application

The Adapter 20489339 is commonly used in 90k psi waterjet pump.

It is often used in combination with other fittings, such as couplings, elbows, and tees, to create a complete 90k psi waterjet pump system.

5. Installation

When installing the Adapter 20489339, it’s important to follow the manufacturer’s guidelines for installation, including using the correct tools and techniques to avoid damaging the adapter or other components.

It’s also important to ensure that the adapter is tightened to the correct torque specifications to prevent leaks and other problems.

You should inspect the adapter regularly for signs of wear or damage, and replace it if necessary to ensure the continued safe and efficient operation of the 90k psi waterjet pump.

90k psi Waterjet Pump 20489339 Adapter, JIC/Pipe, .50 x .38
90k psi Waterjet Pump 20489339 Adapter, JIC/Pipe, .50 x .38 (Item 25)

What are some common problems that can occur with the Adapter 20489339 in 90k psi waterjet pump?

1. Fugas

Leaks can occur if the adapter is not tightened to the correct torque specifications or if the threads are damaged.

Leaks can lead to decreased performance, reduced pressure, and even system failure if not addressed promptly.

2. Damage to Threads

The threads on the adapter can become damaged due to overtightening, cross-threading, or other factors.

Damaged threads can cause leaks or prevent the adapter from fitting properly, which can lead to decreased performance or system failure.

3. Corrosion

The adapter can become corroded over time due to exposure to fluids, chemicals, or environmental factors.

Corrosion can weaken the adapter and cause it to fail, which can lead to decreased performance or system failure.

4. Improper Installation

Improper installation of the adapter can cause problems such as leaks or damage to the threads.

It’s important to follow the manufacturer’s guidelines for installation, including using the correct tools and techniques and applying the correct torque specifications.

5. Incompatible Materials

If the adapter is made from incompatible materials or is not compatible with the fluids or chemicals being used in the system, it can lead to corrosion, leaks, or other problems.

6. Cross-Threaded Fittings

Cross-threading can occur when the adapter is not aligned properly with the fitting it is being installed into, or when the threads are damaged or worn.

Cross-threading can strip or damage the threads on the adapter or the fitting, which can lead to leaks or failure of the 90k psi waterjet pump system.

7. Over-Tightening

Over-tightening the adapter can cause the threads to strip or crack, which can lead to leaks or failure of the 90k psi waterjet pump system.

It’s important to use a torque wrench and follow the manufacturer’s recommended torque specifications for the adapter to avoid over-tightening.

8. Under-Tightening

Under-tightening the adapter can also cause leaks or failure of the fluid system, as the adapter may not be securely fastened to the fitting.

It’s important to use a torque wrench and follow the manufacturer’s recommended torque specifications for the adapter to avoid under-tightening.

9. Wear and Tear

Over time, the adapter can experience wear and tear due to exposure to fluids, chemicals, or environmental factors.

This can cause the threads to become damaged or worn, which can lead to leaks or failure of the 90k psi waterjet pump system.

10. Incompatible Fluids

If the adapter is not compatible with the fluids or chemicals being used in the system, it can lead to corrosion, leaks, or other problems.

It’s important to use an adapter that is made from materials that are compatible with the fluids or chemicals being used in the system.

And you ought to regularly inspect the adapter for signs of corrosion or damage.

What are the torque specifications for tightening the Adapter 20489339 in 90k psi waterjet pump?

The torque specifications for tightening the adapter will depend on several factors, including the material of the adapter, the size of the threads, and the specific application.

In general, the torque specifications for 90k psi waterjet pump system fittings are typically in the range of 15 to 100 foot-pounds (20 to 135 newton-meters).

What are some common lubricants that are compatible with the Adapter 20489339 in 90k psi waterjet pump?

Depending on the material of the adapter and the specific application, here are some common lubricants that are compatible with the adapter:

1. Petroleum-Based Lubricants

Petroleum-based lubricants, such as mineral oil or petroleum jelly, are commonly used for lubricating hydraulic and fluid system components.

These lubricants have good resistance to heat and pressure, and are compatible with a wide range of materials.

2. Synthetic Lubricants

Synthetic lubricants, such as silicone or polyalphaolefin (PAO), are also commonly used for lubricating 90k psi waterjet pump system components.

These lubricants have good resistance to heat, pressure, and oxidation, and are often used in high-temperature or high-pressure applications.

3. Water-Based Lubricants

Water-based lubricants, such as water-soluble cutting fluids or coolants, are commonly used in applications where compatibility with the fluid being used is important.

These lubricants are often used in machining or cutting operations where exposure to water or other fluids is a concern.

4. Dry Film Lubricants

Dry film lubricants, such as molybdenum disulfide or graphite, are often used in applications where the lubricant needs to dry quickly and provide long-lasting lubrication.

These lubricants are especially useful in applications where liquid lubricants are not suitable due to environmental or other concerns.

It’s important to select the appropriate lubricant for the Adapter 20489339 based on the specific application and material of the adapter.

Using an incompatible lubricant can lead to corrosion, damage to the adapter, or contamination of the 90k psi waterjet pump system.

It’s also important to apply the lubricant sparingly and evenly to the threads to avoid excess buildup or contamination of the fluid.

In summary, it’s recommended to follow the manufacturer’s guidelines for lubrication and maintenance of the Adapter 20489339.

And use a lubricant that is compatible with the specific application and 90k psi waterjet pump system.

By using the appropriate lubricant and applying it as necessary, you can help to ensure the reliable and efficient operation of the 90k psi waterjet pump system.

Bomba intensificadora de chorro de agua de 90000 psi
Bomba de chorro de agua de 90k psi

What are some other fittings that are commonly used with the Adapter 20489339 in 90k psi waterjet pump?

There are several other fittings that are commonly used with the Adapter 20489339, depending on the specific application and 90k psi waterjet pump system.

Here are some examples:

1. Coupling

A coupling is a fitting that is used to connect two pipes or hoses together.

Couplings are commonly used with the Adapter 20489339 to create a longer 90k psi waterjet pump system.

2. Elbow

An elbow is a fitting that is used to change the direction of a pipe or hose.

Elbows are commonly used with the Adapter 20489339 to route fluid through tight spaces or around obstacles.

3. Tee

A tee is a fitting that is used to connect three pipes or hoses together.

Tees are commonly used with the Adapter 20489339 to create a branching 90k psi waterjet pump system.

4. Plug

A plug is a fitting that is used to close off the end of a pipe or hose.

Plugs are commonly used with the Adapter 20489339 to seal off unused ports or connections.

5. Union

A union is a fitting that is used to connect two pipes or hoses together, but allows for easy disassembly for maintenance or repairs.

Unions are commonly used with the Adapter 20489339 to create a modular 90k psi waterjet pump system that can be easily disassembled for maintenance or repairs.

These fittings, along with the Adapter 20489339, are essential components in 90k psi waterjet pump.

Any other questions about 90k psi waterjet pump, please contáctenos.