90000 psi 20452956 Tuerca de glándula .38

Categoría:

Descripción

The 20452956 Gland Nut .38 is a small but critical component in 90,000 psi waterjet intensifier pump.

It is responsible for holding the plunger in place and preventing leaks from the intensifier body.

Montaje del intensificador 72170165
Montaje del intensificador 72170165

Artículo

Número de piezaDescripciónCantidadArtículoNúmero de piezaDescripciónCantidad

1

05146592Junta, soporte de Topworks21472162253Desatascador

2

2

20476377Soporte, Topworks21505130091Cartucho de sello hidráulico

2

3

10118206Junta tórica, 1.31×1.56× .1321672175989Brida de retención de buje2

4

05144514Cilindro hidráulico11772158494Conjunto de sello UHP

2

5

05098991Tornillo de cabeza de zócalo, 3/8-16×3-3/481872166738Cilindro UHP

2

6

95688743Arandela de cerradura, .3881972163802Liner

2

7

72101190Conjunto de pistón12020474325Stud, 1-1/8-12×18.31

8

8

10074771Junta tórica, 5.25×5.50× .1322172170157Conjunto de cabezal de sellado

2

9

05120092Anillo de respaldo, 5.25×5.50× .1322272178493Montaje de brida

2

10

72175997Culata hidráulica22320464590Lavadora plana, 1.13

8

11

05097886Tornillo de cabeza de zócalo, 3/4-16×2-1/4122420461761Tuerca hexagonal, 1-1/8-12

8

12

05144183Conjunto del espaciador, interruptor de proximidad22520489339Adaptador, JIC/tubería, 50× .38

1

05144191

Junta tórica, .69× .88× .092672176756Junta tórica, 3.88×4.25× .19

6

13

72141569Kit, interruptor de proximidad2

72134224Interruptor de proximidad

95119012

Tornillo de cabeza de zócalo, 1/4-20×1

90000 psi Waterjet 0.38 Gland Nut
90000 psi 20452956 Tuerca de glándula .38

Here are some important details about the 20452956 Gland Nut .38 used in 90,000 psi waterjet pumps:

– The 20452956 Gland Nut .38 is typically made from high-strength materials like stainless steel or titanium.

These materials can withstand the extreme pressure and temperature conditions involved in waterjet cutting applications.

– The gland nut is designed to be torqued to a specific specification to ensure proper sealing between the plunger and the intensifier body.

Over-tightening or under-tightening the gland nut can cause leaks or other issues with the 90,000 psi waterjet pump.

– Regular inspection and maintenance of the Waterjet 0.38 Gland Nut is important to ensure that it is functioning properly and providing a secure seal.

As time passes, the gland nut may become worn or damaged, which can lead to leaks and other issues.

Replacing the gland nut on a regular schedule can help prevent these issues and prolong the life of the 90,000 psi waterjet pump.

90000 psi Chorro de agua
90,000 psi Waterjet

What are some signs that the gland nut in 90,000 psi waterjet pump needs to be replaced?

1. Fugas

If you notice water or abrasive leaking from the 90,000 psi waterjet pump, this may be a sign that the gland nut is not providing a proper seal between the plunger and the intensifier body.

This may be caused by wear and tear or damage to the gland nut. Leaks can lead to reduced cutting performance, damage to the pump, or other issues.

2. Rendimiento de corte reducido

If you notice that the cutting performance of the 90,000 psi waterjet pump has decreased, this may be a sign that there is a problem with the gland nut or other components in the pump.

Reduced cutting performance may be caused by leaks or other issues that are affecting the pressure or flow of water and abrasive.

3. Unusual noises

If you hear unusual noises coming from the 90,000 psi waterjet pump, such as grinding or clanking sounds, this may be a sign that there is a problem with the gland nut or other components in the pump.

Unusual noises may be caused by wear and tear or damage to the gland nut.

4. Inspección visual

Regular visual inspection of the gland nut and other components in the 90,000 psi waterjet pump can help detect any wear or damage.

If you notice that the gland nut is worn, damaged, or deformed, it may need to be replaced. Signs of wear or damage may include cracks, deformations, or corrosion.

5. Unusual vibrations

If you notice unusual vibrations coming from the 90,000 psi waterjet pump, this may be a sign thatthere is a problem with the gland nut or other components in the pump.

Unusual vibrations may be caused by wear and tear or damage to the gland nut that is affecting the overall performance of the pump.

6. Difficulty tightening or loosening

If you experience difficulty tightening or loosening the gland nut during maintenance or repair tasks, this may be a sign that the gland nut is worn or damaged and needs to be replaced.

If you are unsure about the condition of 90,000 psi 20452956 Gland Nut .38 or any other components of 90,000 psi waterjet cutter, it is recommended to Consulta con nosotros for guidance.